Skip to content
Advanced course · 8 min

Inputs and application for banana

Calibrate a motorised mist blower with clean water, let ORTH turn the calibration into product per tank, and check the label, the weather and the fenced patch before you mix.

The whole course in one video
  1. 1

    Pick the plot first

    Open a new chat and tap Plots (All) under the question box. Choose the plot you want advice for. ORTH then works from that plot’s crop, variety, soil and documents, and from the farm weather.

    For banana Pick one plot of one variety. We picked Lote 2: Gran Enano, 5.43 ha planted in 2008, beside the secondary canal, with a low corner that stays wet and no irrigation. Every answer below is for that plot.

  2. 2

    Start from the Machinery & Equipment button

    For doses and sprayers, tap Machinery & Equipment. ORTH can calibrate your sprayer for a product rate and tank size, check whether your pump and emitters can deliver a plan, or turn a fertigation recipe into injector settings.

    For banana One suggestion is to calibrate a sprayer for a product rate and tank size. We typed our own calibration numbers as the question.

  3. 3

    Give ORTH your calibration

    We gave ORTH an example label rate of 1.0 L of product per hectare, a 12 L tank and our clean-water test: 4.5 L on a strip of 0.25 ha. The aerial cycle was missed, so this is a ground application with a motorised mist blower, on 5.4 ha that leave out the fenced patch. ORTH worked it out: 4.5 ÷ 0.25 = 18 L of mix per hectare, 97.2 L in total, and 5.4 L of product.

  4. 4

    Work out each tank

    ORTH suggested nine equal loads: 600 mL of product in each, topped up with water to 10.8 L, each covering 0.6 ha. That avoids a tiny last tank. With full tanks instead: 666.7 mL per 12 L tank, eight full tanks and a last one of 1.2 L with 66.7 mL. And one warning: the product is part of the tank volume, so do not add it to 12 L of water.

  5. 5

    Check before you mix

    ORTH listed four things to check: the label, the calibration, the weather and the fenced patch. The label: banana, black Sigatoka, mist-blower use, the rate and an 18 L carrier volume, plus the mixing order, rain-free time, the pre-harvest and re-entry intervals and the export residue limits. The calibration: same operator, machine, setting and pace. The weather: rain was forecast that day, so no mixing without time to finish and dry. And the fenced patch: no operator, spray cloud or rinse water may enter it or the canal. Always follow the product label.

  6. 6

    Ask what changes with other equipment

    We asked what changes on Lote 1, with its taller Williams canopy, or for a plantain grower with a manual backpack. ORTH said the rate per hectare stays the same; the calibration changes. On Lote 1, recalibrate in its own rows with water-sensitive cards at three heights, and recalculate the product per tank from the new volume. A manual backpack has no air, so the mist-blower numbers do not transfer, and if the operator cannot reach the top without standing in the spray, it is the wrong tool.

Tip. Calibrate again whenever the operator, the machine setting or the canopy changes. ORTH recalculates the tanks from the new numbers.

Check yourself

1. 4.5 L on a 0.25 ha strip. How much mix per hectare?

2. How do you mix one tank?

3. Lote 1 has a taller canopy. What changes?

4. Rain is forecast this afternoon. What does ORTH say?

Sources: FRAC Banana Working Group · ICA: regulación y control de plaguicidas químicos

More courses for banana and plantain

Inputs and application

Meet ORTH at DATAGRI 2026 · Valladolid, 18–19 Nov · 10% off ORTH Teams & EnterpriseClaim your 10%